ABL/SURSUM

ABL Sursum Earth Leakage Circuit Breaker RP2203 2P 25 A 0,03 A Residual Current Switch 4011721100760
ABL Sursum
£17.95
Fault Current Circuit Breaker In accordance with DIN EN 61008 1/VDE (German electrical engineering Association) 0664 Part 10 SD (SDHC) memory card for AC fault current and vibrant residual current type A. Switching Capacity 10KA at identification of the are Vorsicherung, 2 Division units, 2-pin; Rated current 25 A, Nennfehl current: 30 mA, Rated Voltage 125/230 V AC, 50/60Hz, ambient temperature -25 °C to + 45 °C Number of Poles: 2 Rated voltage is 230 V Rated current is 25 A. Rated residual current is 0.03 A. installation is DIN rail (Reg). Residual current type is a selective type is no. Short circuit resistance (products) is 10 KA. Rated breaking capacity according to EN 60898 is 0.5 Ka. Shock Electric rigidity is 0.2 Ka. Frequency: 50 Hz. Additional components possible is Yes. Type of protection (IP) IP40. Size (according to DIN 43880) is 2nd Width in modular spacing is 2nd Recess Depth is 75 mm. Kurzzeitve Rzögerter Type is no 2P 25 A, 0.03 A ABL Sursum Earth Leakage Circuit Breaker 2P 25 A 0.03 A RP22034011721100760
ABL Sursum Sammelschiene SB 31210 3 Ph. 10qmm Phase Track 4011721011394
ABL Sursum
£13.07
Busbar for circuit breakers of the product ranges S, SL, T and motor protection switch MA in fork shoe guide (without UL and CSA approval), design: 3-phase, maximum rail current: 50A, division units 4/3, cross section: 10mm2 number of phases is 3. Suitable for number of devices is 4. Measurement is 52.5 mm. Cross section is 10mm2. Length is 210mm Rated continuous current Iu is 63 A. Construction of the electrical connection is fork. Insulated is yes. Rated shock voltage is 4kV. Max. Rated operating voltage Ue is 400V. Suitable for devices with N conductor is no. Suitable for devices with auxiliary switch is no 3-Ph. 10 mm² ABL Sursum busbar 3-pH 10qmm SB 312104011721011394
ABL Sursum Automat 1 pol. 6 A B6S1 Grey
ABL Sursum
£3.75
fault-voltage protective switch IEC 60898-1, DIN EN 60898-1, VDE 0641-11 60hZ IP20 weidth: 17,5mm depth: 68,0mm
ABL SURSUM RB1603 circuit breaker - circuit breakers (Grey)
ABL SURSUM
£60.70
Differential/Magnetic Thermal Switches allow protection of people and cables with a single device. Unwanted overload due to overload currents is not possible. Each circuit is assigned its differential/thermal magnet. So each circuit can have all fault current such as electrical leakage. In case of a fault current in a circuit only the circuit concerned is disabled. Nominal fault current 30 mA. Height: 90 mm · Release feature: B/6 kA · Contents: 1 piece. · Nominal Differential Current: 0.03 A · Rated Current: 16 A · Dimensions, Depth: 70 mm · Width: 35 mm · Poles: 1 · Desercice Voltage (details): 230 V/AC · Nom. : 230 V · Type: 1 pole B 16 A · Fuse type (category): FI protection switch · Additional technical data: Power output: 6 kA...
ABL Sursum 1 Gang Electrical Socket, Type E - French, Panel Mount
Blue sky components limited
£6.41
ABL Sursum Thermoplastic French Schuko Socket Outlet Durable Thermoplastic socket outlets, for use with French Schuko 2 pin plus earth plugs, with earth contact in accordance with French and Belgian standards. The flange mounting socket is manufactured to NBN C61-112 and NF C61-314 and is rated at 16A/250 Vac. 16A/250 Vac ratedMaterial ThermoplasticScrewed terminal connection systemFlange mounting
ABL/SURSUM STECKDOSE FÜR HUTSCHIENE 2,5TE 16A 230V
ABL Sursum
£23.75
ABL Sursum plug socket protective cover for top hat rail 2.5 te, 16 A, 230 V SD230 - Keywords: 4004282449690, 230, ABL, sursum, SD230, SCHUTZKONTAKT Power Outlet, for, Hutschiene, 2.5, Te,, Schutzkontaktsteckdose, SCHUTZKONTAKT, Charger.
ABL Sursum Automatic fuses Line safety switch K 25 A 3-pin
ABL SURSUM
£99.79
Technical Specifications: Dimensions: (W x H x D) 53,1 x 82,5 x 68 mm · Nominal current: 25 A · Operating voltage: 230/400 Vac · Release characteristics: K/10kA · Type: 3-pin K 25 A Description: With T-series you have a practice-oriented product range of standard circuit breakers from In = 10 A to 32 A rated current, available with three-poles Low installation height, optimal writeability and easy removal bus bar offer ease of installation.
ABL Sursum Automatic fuses Line safety switch K 16 A 3-pin
ABL Sursum
£86.54
Inside the T Series is a handy range of standard magnetic thermal switches from In = 10A up to a 32A 3 pin rated current. The reduced installation height, the writings can be made optimally and the simple removal of collector bars ensure a remarkable mounting comfort.Height: 82.5 mm · Release feature: K/10 kA · Content: 1 piece. · Rated Current: 16A · Dimension, Depth: 68mm · Width: 53.1mm · Poles: 3 · Desercice Voltage (details): 230/400V/AC · Type: K 16A 3-pin fuse type (category): Magnetic thermal switch...
ABL/SURSUM FI-LEITUNGSSCHUTZSCH.FI/LS C 16A/30MA
ABL Sursum
£84.91
Fils selector switch RCBO 1 x Pole + N characteristic C rated current 16 A Switching Capacity 6kA rated residual current: 30 mA Rated Voltage 230 V AC 4011721155623
ABL SURSUM Automat 3-pol. 10A B10SL3 mit schrau
ABL SURSUM
£59.38
ABL Sursum machine 3 pin. 10 A B10SL3 Screwless outlet clipBuilt-in circuit breaker SLWith clamp PLUG2POWER, with 2 Schraubenlosen outlet plug-in terminals for solid and flexible conductor 1 - 4 mm², completely safe, Zugbelastbar and maintenance-free, Berührungssicher - Short circuit switching capacity Ka, with Messö opening, on/off marking and personalisation window for tool identification, Individual removal of bus composite, Height 83 mm, VDE3 PinNote: The product images may vary slightly sporadically. Please note the title and description.
ABL SURSUM Automat 1 pol. 10A B10SL1 mit schrau
ABL SURSUM
£26.82
ABL Sursum dispenser 1 pin. 10 A B10SL1 Screwless outlet clipBuilt-in circuit breaker SLWith clamp PLUG2POWER, with 2 Schraubenlosen outlet plug-in terminals for solid and flexible conductor 1 - 4 mm², completely safe, Zugbelastbar and maintenance-free, Berührungssicher - Short circuit switching capacity Ka, with Messö opening, on/off marking and personalisation window for tool identification, Individual removal of bus composite, Height 83 mm, VDE1 PinNote: The product images may vary slightly sporadically. Please note the title and description.
ABL SURSUM MS1.6 circuit breaker - circuit breakers (230/400, Black, Grey, Red)
ABL SURSUM
£30.94
Motor overload switch type MS with overload protection, Kurzschlussauslösern, in accordance with DIN VDE 0660 part 102, IEC 60947/4/1, UL approbiert, Rated Current 1/4 "/1 A, short release 12 x IU, with main switch and cutting function, temperature compensates, stagenFailure sensitivity, Nominal power ranges up to 6,3 A at 400 V is Eigenfest, Nominal power areas > 6,3 A at 400 V have a switching capacity of 6 KA Überlastauslöser Power Setting is 1/4.. 1 A. adjustment range of the Unverzögerten Short circuit trigger is 12.. 12 A. phase Ausfal Lemp sensitive to is Yes. Release Technology is magnetic. Rated continuous current IU 1 A. Rated Operational Performance at AC-3 400 V is 0.25 kW. Type of connection most circuit is screw connection. Device is Ebauart installation device with a snug mounting technology. With integrated auxiliary switches is no. With built in low voltage trigger is no. Number of Poles: is 3 rated short circuit between made from switching power supply ICU at 400 V AC is 100 KA. Type of protection (IP) is IP20 1/4 "-1 A ABL Sursum motor protection switch 1/4"